Key result
A regression equation (cranial/caudal intercept -16.4, slope LAO/RAO +0.53; P<0.0001) was identified to help operators determine the optimal fluoroscopic projection angle during TAVI.
Observational (n=50)
p-value: p=<0.0001
A simple reference projection angle starting at LAO 8.9, Caudal -11.4 can help operators determine the optimal fluoroscopic working view during TAVI.
May simplify TAVI fluoroscopic optimization; leaves open prospective validation of procedural outcomes.
INTRODUCTION: An optimal fluoroscopic working view projection (OP) with all three aortic sinuses aligned is crucial during trans-catheter aortic valve implantation (TAVI). The aim of this study was to identify simple reference projection angles, which would act as a starting point for the operator to help determine OP for patients undergoing TAVI. METHODS: During the period under consideration, 50 patients underwent TAVI. Procedural data and outcomes were collected prospectively on a dedicated database. Optimal angiographic deployment angles were achieved for all patients by starting in an anteroposterior caudal 15 degrees projection and then adjusting according to the initial image, with multiple small volume contrast injections undertaken to determine when all three aortic cusps were aligned (OP). RESULTS: OP angles for the 50 cases were plotted on a graph. After normality testing confirmed that all angles were normally distributed, regression analysis enabled a regression line to be calculated. The equation for the regression line was defined as cranial/caudal intercept -16.4 ± 1.5 (SE of the coefficient), P < 0.0001, slope of regression line LAO/RAO + 0.53 ± 0.1 (SE of the coefficient SE), P < 0.0001). CONCLUSIONS: As the regression line and its equation represents an acceptable estimate of the true relationship between Cranial/Caudal and LAO/RAO, to determine OP while remaining close to the regression line we suggest starting in LAO = 8.9, Caudal = -11.4 (which represent the mean values of these two variables), and then increasing the caudal angle by approximately 0.5 degrees for every increase of 1 degree of the LAO angle or decreasing the caudal angle by 0.53 degrees for every decrease of 1 degree in LAO until all three aortic sinuses are in line which represents OP.
No takes yet. Share an insight, caveat, or question.
Cockburn et al. (2012) conducted an observational in Transcatheter aortic valve implantation (n=50). Optimal fluoroscopic working view projection determination was evaluated on Relationship between Cranial/Caudal and LAO/RAO angles for optimal projection (p=<0.0001). A regression equation (cranial/caudal intercept -16.4, slope LAO/RAO +0.53; P<0.0001) was identified to help operators determine the optimal fluoroscopic projection angle during TAVI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: