Key result
A novel radial balloon catheter-based method produced similar tissue stiffness measurements for the pulmonary artery and pulmonary valve regions compared to traditional uniaxial tensile testing, demonstrating its potential for non-destructive in situ measurement.
Why the study?
Data capturing cardiovascular tissue geometry and mechanical properties in pediatric populations and large animal models are limited, which hinders the development of pediatric cardiovascular devices.
Does a novel radial balloon catheter-based method accurately measure tissue stiffness compared to uniaxial tensile testing in juvenile porcine pulmonary artery and valve tissue?
Does a novel radial balloon catheter-based method accurately measure tissue stiffness compared to uniaxial tensile testing in juvenile porcine pulmonary artery and valve tissue?
A novel balloon catheter-based technique effectively measures tissue stiffness in juvenile porcine pulmonary arteries, providing critical baseline data for pediatric cardiovascular prosthesis development.
Characterization of cardiovascular tissue geometry and mechanical properties of large animal models is essential when developing cardiovascular devices such as heart valve replacements. These datasets are especially critical when designing devices for pediatric patient populations, as there is often limited data for guidance. Here, we present a previously unavailable dataset capturing anatomical measurements and mechanical properties of juvenile Yorkshire (YO) and Yucatan (YU) porcine main pulmonary artery (PA) and pulmonary valve (PV) tissue regions that will inform pediatric heart valve design requirements for preclinical animal studies. In addition, we developed a novel radial balloon catheter-based method to measure tissue stiffness and validated it against a traditional uniaxial tensile testing method. YU piglets, which were significantly lower weight than YO counterparts despite similar age, had smaller PA and PV diameters (7.6–9.9 mm vs. 10.1–12.8 mm). Young’s modulus (stiffness) was measured for the PA and the PV region using both the radial and uniaxial testing methods. There was no significant difference between the two breeds for Young’s modulus measured in the elastic (YU PA 84.7 ± 37.3 kPa, YO PA 79.3 ± 15.7 kPa) and fibrous regimes (YU PA 308.6 ± 59.4 kPa, YO PA 355.7 ± 68.9 kPa) of the stress-strain curves. The two testing techniques also produced similar stiffness measurements for the PA and PV region, although PV data showed greater variation between techniques. Overall, YU and YO piglets had similar PA and PV diameters and tissue stiffness to previously reported infant pediatric patients. These results provide a previously unavailable age-specific juvenile porcine tissue geometry and stiffness dataset critical to the development of pediatric cardiovascular prostheses. Additionally, the data demonstrates the efficacy of a novel balloon catheter-based technique that could be adapted to non-destructively measure tissue stiffness in situ.
No takes yet. Share an insight, caveat, or question.
Sutherland et al. (2022) studied Healthy animal models for pediatric cardiovascular devices (n=12). Radial balloon catheter-based testing method vs. Uniaxial tensile testing was evaluated on Young's modulus (tissue stiffness) of the pulmonary artery and pulmonary valve regions. A novel radial balloon catheter-based method produced similar tissue stiffness measurements for the pulmonary artery and pulmonary valve regions compared to traditional uniaxial tensile testing, demonstrating its potential for non-destructive in situ measurement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: