Key result
Radiofrequency catheter ablation of the atrioventricular junction was complicated by recurrent sustained ventricular arrhythmia despite rapid ventricular pacing, recurring 3 months after discharge.
Case Report (n=1)
This case report highlights the rare but severe complication of recurrent sustained ventricular arrhythmia following RF AV junction ablation, which may explain sudden death cases post-procedure.
Answers are grounded in this paper and cite their sources.
May warrant vigilance for late ventricular arrhythmia after AV junction ablation; single case leaves open incidence and prevention strategies.
Recurrent ventricular tachycardia and ventricular fibrillation were observed immediately after RF ablation of the AV junction in a 64-year-old man. This arrhythmia was preceded by ventricular bigeminy and a long-short sequence. It was not associated with prolongation of the QT interval compared to baseline, and recurred 3 months later despite ventricular pacing at 90 beats/min. This is the first reported case of sustained ventricular arrhythmia complicating RF AV junction ablation despite rapid ventricular pacing, and recurring 3 months after discharge. It may explain the rare cases of sudden death complicating this procedure.
No takes yet. Share an insight, caveat, or question.
Azar et al. (1998) conducted a case report in Recurrent ventricular tachycardia and ventricular fibrillation (n=1). Radiofrequency catheter ablation of the atrioventricular junction was evaluated on Recurrent ventricular tachycardia and ventricular fibrillation. Radiofrequency catheter ablation of the atrioventricular junction was complicated by recurrent sustained ventricular arrhythmia despite rapid ventricular pacing, recurring 3 months after discharge.