Key result
Mechanical intracardiac echocardiography correctly identified structures in 100% of patients, provided better anatomy definition than TEE in 4.5%, and changed the planned device in 24.4%.
Why the study?
Does intracardiac echocardiography with a mechanical probe improve structure identification and procedural planning compared to transesophageal echocardiography in patients undergoing interatrial shunt closure?
Observational (n=537)
Does intracardiac echocardiography with a mechanical probe improve structure identification and procedural planning compared to transesophageal echocardiography in patients undergoing interatrial shunt closure?
Mechanical ICE is a safe and effective alternative to TEE for guiding interatrial shunt closure, frequently providing additional anatomical information that alters procedural planning.
Answers are grounded in this paper and cite their sources.
May support mechanical ICE for interatrial shunt closure planning; leaves open superiority over TEE in randomized trials.
BACKGROUND: The clinical outcome benefit of intracardiac echocardiography (ICE) with a mechanical probe during congenital heart disease interventions has not been fully investigated. We reported the long-term results of a prospective registry of interatrial shunt closure guided by mechanical ICE. METHODS: We enrolled 537 patients (mean age 48 ± 19.0 years, 378 females) submitted to ICE-aided procedures in a prospective registry over a 10-year period (September 2003-September 2013). All patients underwent transesophageal echocardiography (TEE) before the planned procedure. We evaluated (1) structure identification capability, (2) fossa ovale and interatrial septum component measurement, (3) procedure monitoring capability, (4) procedural and fluoroscopy times, and radiograph dose, (5) probe-related complications. RESULTS: ICE was successfully performed and was able to correctly identify the structures previously assessed by TEE in all patients. In 24 patients (4.5%), ICE allowed better anatomy definition than TEE. In 35 other patients (6.5%), ICE identified structures not observed by TEE, which led to change indications to interventions or the operative technique to be used. In 131 patients (24.4%), ICE evaluation led to change the planned device to be implanted. There was only one probe-related complication (0.2%). CONCLUSIONS: Mechanical ICE may offer a valid alternative to conventional TEE in guiding congenital heart disease interventional procedures.
No takes yet. Share an insight, caveat, or question.
Rigatelli et al. (2014) conducted an observational in Congenital heart disease (interatrial shunt) (n=537). Intracardiac echocardiography (ICE) with a mechanical probe vs. Transesophageal echocardiography (TEE) was evaluated on Structure identification capability and procedural impact. Mechanical intracardiac echocardiography correctly identified structures in 100% of patients, provided better anatomy definition than TEE in 4.5%, and changed the planned device in 24.4%.
Synapse has enriched 10 related papers. Consider them for comparative context: