This is the authors' abstract. We don't add key points for this paper.
This paper describes the control analysis and design of an ac-to-ac three-phase mobile utility power supply using a matrix converter capable of high-quality 50-, 60-, and 400-Hz output voltage and reduced input harmonic distortion. Instead of the traditional structure employing a diode bridge rectifier, a dc link and a pulsewidth-modulated inverter, a three-phase-to-three-phase direct ac-ac (matrix) converter has been used as the power-conditioning core of the system, working in conjunction with input and output LC low-pass filters. An optimizing control design method using a genetic algorithm approach has been used, which yields designs to minimize a cost function, taking into account transient and steady-state output voltage performance targets, together with robustness to different operative conditions and system parameters drift. Simulation and experimental tests have demonstrated that the system meets the power-quality requirements of the application.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Zanchetta et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: