Key result
Four-quadrant visualization of systemic circulatory equilibrium guides RV failure management after LVAD implantation.
A novel four-quadrant visualization of systemic circulatory equilibrium provides a physiological framework for managing circulatory malfunction, such as right ventricular failure after LVAD implantation.
Answers are grounded in this paper and cite their sources.
May guide post-LVAD RV failure management; extends circulatory modeling but leaves open prospective validation.
Systemic circulatory dynamics are regulated by various negative feedback systems, including cardiac, arterial, venous, and renal functions, as well as autonomic nervous systems. The present novel four-quadrant presentation of their functions allows clear visualization of dynamic organ-to-organ interactions that can lead to a new circulatory equilibrium after therapeutic intervention. This new system physiological framework can serve as a useful guide for prompt and optimal management of circulatory malfunction.
No takes yet. Share an insight, caveat, or question.
Maeda et al. (2021) conducted a review in Right ventricular failure after left ventricular assist device implantation. Four-quadrant visualization of systemic circulatory equilibrium was evaluated. A novel four-quadrant visualization of systemic circulatory equilibrium provides a physiological framework to guide the management of right ventricular failure after LVAD implantation.
Synapse has enriched 10 related papers. Consider them for comparative context: