This is the authors' abstract. We don't add key points for this paper.
Noninvasive detection of glucose (NGD) is important because ∼10% of the global population is suffering from diabetes. Herein, a three-dimensional (3D) micro-/mesoporous structure, i.e., a CoNi-N nanosheet-coated GaN 3D scaffold (CoNi-N@GaN-3S), was proposed for detecting saliva glucose, where the GaN scaffold can provide a large open surface for nanosheet decoration, while the catalytic nanosheets can increase the surface area and prevent the GaN-3S from anodic corrosion. Moreover, it was found that high-temperature ammoniation of CoNi can lead to dense atomic holes and an N-terminated surface (CoNi-N), which promoted the ionization of CoNi with a higher catalytic activity. It is the first time that dense atomic holes have been observed in CoNi to our knowledge. The designed CoNi-N@GaN-3S sensor was applied to the electrochemical detection of glucose with a low limit of detection (LOD) of 60 nM and a high sensitivity, selectivity, and stability. In addition, detection of human-saliva glucose was realized with an LOD of 5 μM, which was more than 4-fold lower than reported reliable LODs. An integrated sensor with a low consumption of saliva sample was demonstrated for NGD.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: