Key result
Carotid Doppler ultrasound demonstrated a diagnostic accuracy of 53.12%, with 54.55% sensitivity and 50% specificity, for detecting anechoic carotid artery thrombus compared to CT angiography.
Why the study?
The study aimed to evaluate the diagnostic accuracy of carotid Doppler ultrasound in detecting anechoic carotid artery thrombus compared with CT angiography as the gold standard.
Does carotid Doppler ultrasound accurately detect anechoic carotid artery thrombus compared to CT angiography in patients undergoing stroke workup?
Observational (n=32)
No
Does carotid Doppler ultrasound accurately detect anechoic carotid artery thrombus compared to CT angiography in patients undergoing stroke workup?
Carotid Doppler ultrasound demonstrated a low diagnostic accuracy of 53% for detecting anechoic carotid thrombus, confirming that CT angiography remains the gold standard when clinical suspicion is high.
Answers are grounded in this paper and cite their sources.
Does not support Doppler as a reliable alternative to CTA; leaves open the need for prospective validation in stroke imaging protocols.
Objective In this study, we aimed to assess the diagnostic accuracy of carotid Doppler ultrasound (CDU) in detecting anechoic carotid artery thrombus when compared to CT angiography (CTA) as the gold standard. Materials and methods This prospective comparative study was conducted at the Radiology Department of the Pakistan Institute of Medical Sciences, Islamabad from January 2022 to May 2022. The study enrolled 32 patients who met the inclusion criteria. We evaluated patients admitted to the neurology ward/OPD who were referred to radiology as part of a stroke workup based on their clinical examination and medical history. In all patients, CDU was used to detect free-floating thrombus (FFT)/anechoic thrombus. CTA was used as the gold standard to assess the diagnostic accuracy of CDU. Results The mean age of the study participants was 45.63 ± 7.05 years (range: 33-59 years). Out of 32 patients, 19 (59.4%) were male and 13 (40.6%) were female. The results of CDU were confirmed by CTA in all patients. The diagnostic accuracy of CDU was 53.12% for detecting FFT. The values for sensitivity (54.55%), specificity (50%), positive predictive value (PPV, 70.59%), and negative predictive value (NPV, 33.33%) were also calculated. Conclusion Despite the limited sample size, the study concludes that CDU has a diagnostic accuracy of 53%. CTA still remains the gold standard imaging modality for anechoic thrombus if strong clinical suspicion is present.
No takes yet. Share an insight, caveat, or question.
Khan et al. (2022) conducted an observational in Suspected carotid artery thrombus (n=32). Carotid Doppler ultrasound vs. CT angiography was evaluated on Diagnostic accuracy for detecting anechoic thrombus. Carotid Doppler ultrasound demonstrated a diagnostic accuracy of 53.12%, with 54.55% sensitivity and 50% specificity, for detecting anechoic carotid artery thrombus compared to CT angiography.
Synapse has enriched 10 related papers. Consider them for comparative context: