Key result
Near-infrared spectroscopy monitoring during carotid endarterectomy under general anesthesia detected clamping ischemia with 100% sensitivity and 90.6% specificity using a >25% reduction cutoff.
Why the study?
Does near-infrared spectroscopy (NIRS) reliably detect clamping ischemia during carotid endarterectomy under general anesthesia?
Observational (n=473)
Does near-infrared spectroscopy (NIRS) reliably detect clamping ischemia during carotid endarterectomy under general anesthesia?
Effect estimate: Sensitivity 100%, Specificity 90.6%
NIRS monitoring during carotid endarterectomy under general anesthesia is a highly sensitive and reliable method for detecting clamping ischemia and guiding the need for shunting.
Guidelines do not include cerebral oximetry among monitoring for carotid endarterectomy (CEA). The purpose of this study was to evaluate the reliability of near-infrared spectroscopy (NIRS) in the detection of clamping ischemia and in the prevention of clamping-related neurologic deficits using, as a cutoff for shunting, a 20% regional cerebral oxygen saturation (rSO(2)) decrease if persistent more than 4 minutes, otherwise a 25% rSO(2) decrease. Bilateral rSO(2) was monitored continuously in patients undergoing CEA under general anesthesia (GA). Data was recorded after clamping, declamping, during shunting and lowest values achieved. Preoperative neurologic, CT-scan, and vascular lesions were recorded. We reviewed 473 cases: 305 males (64.5%) mean age 73.3 ± 7.3. Three patients presented transient ischemic deficits at awakening, no perioperative stroke or death; 41 (8.7%) required shunting: 30 based on the initial rSO(2) value and 11 due to a decrease during surgery. Using the ROC curve analysis we found, for a >25% reduction from baseline value, a sensitivity of 100% and a specificity of 90.6%. Reliability, PPV, and NPV were 95.38%, 9%, and 100%, respectively. In conclusion, this study indicates the potential reliability of NIRS monitoring during CEA under GA, using a cutoff of 25% or a cutoff of 20% for prolonged hypoperfusion.
No takes yet. Share an insight, caveat, or question.
Pedrini et al. (2011) conducted an observational in Carotid endarterectomy (CEA) (n=473). Near-infrared spectroscopy (NIRS) monitoring was evaluated on Detection of clamping ischemia using a >25% reduction from baseline rSO(2) (Sensitivity 100%, Specificity 90.6%). Near-infrared spectroscopy monitoring during carotid endarterectomy under general anesthesia detected clamping ischemia with 100% sensitivity and 90.6% specificity using a >25% reduction cutoff.