Key result
NIRS correlates with TCD during carotid endarterectomy, identifying cerebral hypoperfusion at a ~12% rSO2 drop.
Why the study?
There has been no gold standard for intraoperative monitoring in carotid endarterectomy (CEA).
Does near-infrared spectroscopy (NIRS) monitoring correlate with transcranial Doppler (TCD) for detecting intraoperative cerebral hypoperfusion in patients undergoing carotid endarterectomy?
Observational (n=84)
No
Does near-infrared spectroscopy (NIRS) monitoring correlate with transcranial Doppler (TCD) for detecting intraoperative cerebral hypoperfusion in patients undergoing carotid endarterectomy?
Effect estimate: Pearson correlation index 0.581
p-value: p=<0.001
NIRS is a reliable monitoring tool during carotid endarterectomy, with a 12.3% decrease in rSO2 serving as an optimal threshold for detecting intraoperative cerebral hypoperfusion.
NIRS monitoring may help detect hypoperfusion in CEA; leaves open validated thresholds before routine adoption.
There has been no gold standard for intraoperative monitoring in carotid endarterectomy (CEA) till now. The purpose of the current study was to investigate the value of near-infrared spectroscopy (NIRS) monitoring in CEA and explore the thresholds for intraoperative cerebral hypoperfusion. Eighty-four consecutive patients who underwent CEA surgery in Xuan Wu Hospital of Capital Medical University from August 2015 to June 2016 were enrolled in this study. All patients were intraoperatively monitored by transcranial Doppler ultrasonography (TCD) and NIRS. Regional oxygen saturation (rSO 2 ) monitored by NIRS and blood flow velocity of the middle cerebral artery (V-MCA) monitored by TCD were continuously recorded. Correlation analysis was conducted for NIRS and TCD monitoring values. Intraoperative shunting was performed in five patients according to the TCD monitoring results and surgeon preference. During clamping of the carotid artery, the Pearson correlation index between rSO 2 and V-MCA was 0.581 (P<0.001). A cut-off of 12.3% decrease of rSO 2 was identified as the optimal threshold for intraoperative hypoperfusion indicated by TCD monitoring, when the sensitivity and specificity were 64.3% and 90.0%, respectively, with a 0.570 Kappa value. Physical examination immediately after operation showed no ischemic injury occurred, and no death and stroke occurred during the postoperative hospitalization. Our study demonstrated that NIRS could serve as a favorable monitoring tool during CEA. A 12.3% decrease of rSO 2 could be adopted as a reliable threshold for intraoperative cerebral hypoperfusion.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2018) conducted an observational in Carotid endarterectomy (CEA) (n=84). Near-infrared spectroscopy (NIRS) monitoring vs. Transcranial Doppler ultrasonography (TCD) monitoring was evaluated on Correlation between regional oxygen saturation (rSO2) by NIRS and blood flow velocity of the middle cerebral artery (V-MCA) by TCD during carotid artery clamping (Pearson correlation index 0.581, p=<0.001). Near-infrared spectroscopy monitoring during carotid endarterectomy correlated with transcranial Doppler (r=0.581, P<0.001), with a 12.3% rSO2 decrease indicating cerebral hypoperfusion.