Key result
4D ultrasound demonstrated very good reliability for maximum aortic diameter and circumferential strain in non-atherosclerotic aortae, but low reliability in calcified aortae.
Why the study?
Four-dimensional ultrasound enables imaging of aortic wall expansion with high resolution, but its in vivo reliability for low-measure values was unknown.
Is 4D ultrasound a reliable method for assessing cyclic diameter changes and circumferential strain in the infrarenal aorta?
Observational (n=22)
Is 4D ultrasound a reliable method for assessing cyclic diameter changes and circumferential strain in the infrarenal aorta?
4D ultrasound provides reliable in vivo assessment of kinematic properties in non-aneurysmal, non-calcified infrarenal aortae, independent of observer experience.
Answers are grounded in this paper and cite their sources.
4D-US may aid strain assessment in non-calcified aortae; leaves open reliability in calcified vessels and clinical adoption.
OBJECTIVES: The four-dimensional ultrasound (4D-US) enables imaging of the aortic segment and simultaneous determination of the wall expansion. The method shows a high spatial and temporal resolution, but its in vivo reliability is so far unknown for low-measure values. The present study determines the intraobserver repeatability and interobserver reproducibility of 4D-US in the atherosclerotic and non-atherosclerotic infrarenal aorta. METHODS: In all, 22 patients with non-aneurysmal aorta were examined by an experienced examiner and a medical student. After registration of 4D images, both the examiners marked the aortic wall manually before the commercially implemented speckle tracking algorithm was applied. The cyclic changes of the aortic diameter and circumferential strain were determined with the help of custom-made software. The reliability of 4D-US was tested by the intraclass correlation coefficient (ICC). RESULTS: The 4D-US measurements showed very good reliability for the maximum aortic diameter and the circumferential strain for all patients and for the non-atherosclerotic aortae (ICC >0.7), but low reliability for circumferential strain in calcified aortae (ICC = 0.29). The observer- and masking-related variances for both maximum diameter and circumferential strain were close to zero. CONCLUSIONS: Despite the low-measured values, the high spatial and temporal resolution of the 4D-US enables a reliable evaluation of cyclic diameter changes and circumferential strain in non-aneurysmal aortae independent from the observer experience but with some limitations for calcified aortae. The 4D-US opens up a new perspective with regard to noninvasive, in vivo assessment of kinematic properties of the vessel wall in the abdominal aorta.
No takes yet. Share an insight, caveat, or question.
Derwich et al. (2021) conducted an observational in Non-aneurysmal aorta (n=22). 4D ultrasound (4D-US) was evaluated on Intraobserver repeatability and interobserver reproducibility of maximum aortic diameter and circumferential strain (ICC >0.7 for non-atherosclerotic aortae; ICC = 0.29 for calcified aortae). 4D ultrasound demonstrated very good reliability for maximum aortic diameter and circumferential strain in non-atherosclerotic aortae, but low reliability in calcified aortae.