Key result
Prosthetic heart valves were associated with the presence of micro-embolic signals in 67% of patients, closely related to the cavitation phenomenon, whereas no signals were detected in patients without prosthetic valves.
Why the study?
Are micro-embolic signals detected by TCD in patients with prosthetic heart valves related to echocardiographic cavitation or hematological markers?
Observational (n=20)
Are micro-embolic signals detected by TCD in patients with prosthetic heart valves related to echocardiographic cavitation or hematological markers?
Micro-embolic signals are frequently detected in patients with prosthetic heart valves and are closely related to the cavitation phenomenon observed on TEE, rather than standard anticoagulation intensity.
Answers are grounded in this paper and cite their sources.
Micro-embolic signals on TCD may reflect cavitation on TEE in prosthetic valves; leaves open clinical relevance pending prospective studies.
We undertook TCD examination combined with transesophageal echocardiography (TEE) and measurements of hematological markers for coagulation, fibrinolysis and platelet function to clarify the clinical significance of micro-embolic signals derived from the heart. We examined nine patients with prosthetic valves including two with cardioembolic stroke (CE) and 11 CE patients without prosthetic valves. All the patients were receiving anticoagulation therapy at the time of the study. TCD study demonstrated 3-54/30 min micro-embolic signals in six of the nine patients with prosthetic valves, but no signal in those without valve replacement. TEE study demonstrated cavitation phenomenon in eight of the nine patients with prosthetic valves, but in none of the patients without valve replacement. No other findings of TEE or hematological examination were correlated with the frequncy of micro-embolic signals. These results indicate a close relationship between cavitation phenomenon and micro-embolic signals in patients with prosthetic valve. Ordinary anticoagulation (INR: international normalized ratio 2.0-3.0) does not reduce the frequency of micro-embolic signals in patients with prosthetic heart valve. However, very high intensity anticoagulation (INR>3.5) might decrease the frequency of micro-embolic signals. Further studies are necessary to clarify the clinical significance of microembolic signals.
No takes yet. Share an insight, caveat, or question.
Yoshimoto et al. (1997) conducted an observational in Prosthetic heart valves and cardioembolic stroke (n=20). Prosthetic heart valves vs. Cardioembolic stroke without prosthetic valves was evaluated on Presence of micro-embolic signals on transcranial Doppler. Prosthetic heart valves were associated with the presence of micro-embolic signals in 67% of patients, closely related to the cavitation phenomenon, whereas no signals were detected in patients without prosthetic valves.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: