Answers are grounded in this paper and cite their sources.
A novel oxidative absorption process of elemental mercury (Hg 0 ) from flue gas using a Mn 2+ -modified Fe 3+ /H 2 O 2 wet scrubbing system (i.e., Mn 2+ -modified Fenton-like wet scrubbing system) was proposed. The influence of several technological parameters (concentration of Fe 3+, H 2 O 2, and Mn 2+, solution pH value, solution temperature, and concentration of Hg 0, NO, and SO 2 ) on Hg 0 absorption in a bubbling stirred reactor was investigated. On the basis of the detection of free radicals and reaction products, the routes and mechanism of Hg 0 oxidative absorption were also proposed. Results revealed that adding Mn 2+ greatly promoted Hg 0 absorption using a Fenton-like wet scrubbing system. The enhancement role resulted from generating more • OH radicals (they were produced from the synergistic effect of Mn 2+ and Fe 3+ in a Mn 2+ -modified Fenton-like wet scrubbing system). Hg 0 removal efficiency was elevated via increasing the concentration of Fe 3+, Mn 2+, or H 2 O 2 and was decreased by increasing the concentration of Hg 0, NO, or SO 2 . Increasing the solution temperature and pH value showed double influence on Hg 0 absorption. Hg 0 was oxidized by • OH and H 2 O 2, and • OH played a key role. • OH was found to be produced from three sources: (1) Fe 2+ /H 2 O 2 system, (2) Mn 2+ /H 2 O 2 system, and (3) by the synergistic role of Fe 3+ and Mn 2+ in a Mn 2+ -modified Fenton-like wet scrubbing system.