Key result
Balloon dilatation for aortic re-coarctation improved aortic helical flow and left ventricular blood flow distribution by reducing afterload, as evaluated by 4D flow MRI.
Why the study?
Detecting LV functional changes from increased afterload in re-coarctation of the aorta is difficult when LV contractile force is preserved, and intraventricular blood flow before and after treatment has not been previously evaluated.
Does balloon dilatation improve intraventricular haemodynamics and helical flow in a patient with aortic re-coarctation?
Case Report (n=1)
Does balloon dilatation improve intraventricular haemodynamics and helical flow in a patient with aortic re-coarctation?
4D flow MRI demonstrated that balloon dilatation for aortic re-coarctation improves aortic helical flow and left ventricular haemodynamics by reducing afterload.
Answers are grounded in this paper and cite their sources.
May support 4D flow MRI to evaluate response to balloon dilatation in re-coarctation; hypothesis-generating and should not yet change practice.
Background: Long-term re-coarctation of the aorta can cause aortic dilatation, hypertension, and cardiac dysfunction due to increased left ventricular (LV) afterload. It is difficult to detect changes in LV function due to increased afterload if the contractile force of the left ventricle is maintained. Herein, we have reported a case of re-coarctation of the aorta, for which four-dimensional (4D) flow magnetic resonance imaging (MRI) scan was obtained both before and after balloon dilatation for aortic re-coarctation. Ultimately, improvement in aortic helical flow and LV haemodynamics was observed. Case summary: A 29-year-old female was diagnosed with coarctation of the aorta and a bicuspid aortic valve after birth and underwent surgery at 1 month. At 8 years of age, she underwent balloon dilatation for re-coarctation. At the age of 28 years, she was diagnosed with re-coarctation triggered by hypertension. She underwent balloon dilatation as her cardiac catheterization revealed a systolic pressure gradient of 40 mmHg. Pretreatment 4D flow MRI demonstrated helical flow in the ascending aorta and descending thoracic aorta and LV blood flow analysis revealed a decrease in LV kinetic energy during systole; these improved after treatment. Discussion: The use of helical flow evaluation by 4D flow MRI for aortic re-coarctation is well known in clinical practice. However, our report is the first to evaluate intraventricular blood flow before and after the re-coarctation treatment. The MRI evaluation demonstrated that the helical flow and LV blood flow distribution improved after re-coarctation treatment due to the reduction of afterload.
No takes yet. Share an insight, caveat, or question.
Shibagaki et al. (2023) conducted a case report in Re-coarctation of the aorta (n=1). Balloon dilatation vs. Pretreatment was evaluated on Intraventricular haemodynamic changes (helical flow and LV blood flow distribution). Balloon dilatation for aortic re-coarctation improved aortic helical flow and left ventricular blood flow distribution by reducing afterload, as evaluated by 4D flow MRI.
Synapse has enriched 10 related papers. Consider them for comparative context: