Key result
Cryopreserved homograft valves implanted in the pulmonary position demonstrated good mid-term function with an operative mortality of 3.3% (2/56) and 51 long-term survivors.
Observational (n=56)
Answers are grounded in this paper and cite their sources.
Cryopreserved homograft valves function well in the right ventricular outflow tract with low operative mortality and good mid-term clinical outcomes in pediatric and young adult patients.
Since September 1985, 60 cryopreserved homograft valves (12 aortic and 48 pulmonary) have been implanted in the pulmonary position in 56 patients. There were 34 primary operations and 26 reoperations. The ages ranged from 15 days to 22 years; the follow-up ranged from 1 month to 5 1/2 years. The operative mortality was 3.3% (2/56). There were two late deaths (not valve related). Five patients underwent replacement of the homograft; in one patient the homograft was replaced with a heterograft valve. Pathological analysis of the explanted homografts revealed calcification of the wall with satisfactory leaflet function. The leaflets were relatively acellular. No evidence of inflammation or rejection was detected. Four explants were performed for nonvalve-related indications. There are 51 long-term survivors with a homograft in place. Forty-eight are in excellent condition; three are mildly symptomatic (not valve related). Benign pulmonary insufficiency murmurs are present in 29 patients. The presence of trivial or mild insufficiency was independent of the technique of implantation. In general, cryopreserved homograft valves function well in the right ventricular outflow tract. Longer term follow-up is necessary to confirm the superiority of the cryopreserved homograft when compared to the porcine heterograft in the right ventricular outflow tract.
No takes yet. Share an insight, caveat, or question.
Lamberti et al. (1991) reported an observational. Cryopreserved homograft valves in the pulmonary position was evaluated on Operative mortality. Cryopreserved homograft valves implanted in the pulmonary position demonstrated good mid-term function with an operative mortality of 3.3% (2/56) and 51 long-term survivors.
Synapse has enriched 10 related papers. Consider them for comparative context: