Key result
Redo tricuspid surgery using a beating-heart approach without replacing the existing first-generation mechanical mitral prosthesis was safe and effective in 2 patients at 5-year follow-up.
Why the study?
Does a beating-heart approach without prophylactic mitral valve replacement provide safe outcomes in patients undergoing redo tricuspid surgery decades after 1st-generation mechanical mitral valve replacement?
Case Report (n=2)
Does a beating-heart approach without prophylactic mitral valve replacement provide safe outcomes in patients undergoing redo tricuspid surgery decades after 1st-generation mechanical mitral valve replacement?
Leaving a normally functioning first-generation mechanical mitral prosthesis in situ during redo tricuspid surgery using a beating-heart approach appears safe and effective at 5-year follow-up.
Answers are grounded in this paper and cite their sources.
May support beating-heart redo tricuspid surgery in select high-risk cases; leaves open need for larger prospective validation.
Background In patients with remarkably enlarged cardiac chambers and history of implantation of older types of mitral valve prosthesis, the considerations for reoperative tricuspid valve surgery are not limited to the risks of sternal reentry but also include the dilemma of whether to carry out prophylactic replacement of the normal functioning but outdated prosthesis or leave it in situ. Methods We reviewed our surgical strategy and postoperative 5-year follow-up findings in two patients who underwent redo tricuspid surgery 3 to 4 decades after mechanical mitral valve replacement. Both patients presented with significant symptoms of progressive right heart failure due to severe tricuspid regurgitation, despite optimal medical therapy. Results We found the beating-heart approach to be an effective and safe method for redo tricuspid surgery. Both first-generation mitral mechanical prostheses were not replaced and have remained well functional upon the patients' postoperative 5-year follow-up, respectively. Conclusion For patients with normal functioning first-generation mechanical mitral prostheses, whether to prophylactically replace the prosthesis should be based on an individualized risk-benefit analysis.
No takes yet. Share an insight, caveat, or question.
Chow et al. (2018) conducted a case report in Severe tricuspid regurgitation and progressive right heart failure (n=2). Redo tricuspid surgery via beating-heart approach without prophylactic mitral valve replacement was evaluated on Prosthesis functionality and surgical safety. Redo tricuspid surgery using a beating-heart approach without replacing the existing first-generation mechanical mitral prosthesis was safe and effective in 2 patients at 5-year follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: