Key result
Genetic variants in ITGA9 and SOX5 were significantly associated with left atrial remodeling (low voltage areas and dilatation) and atrial fibrillation recurrence after catheter ablation.
Why the study?
Do PR interval candidate genes associate with left atrial remodeling and arrhythmia recurrence following catheter ablation in patients with atrial fibrillation?
Cohort (n=660)
No
Do PR interval candidate genes associate with left atrial remodeling and arrhythmia recurrence following catheter ablation in patients with atrial fibrillation?
The ITGA9 and SOX5 genes are associated with left atrial remodeling and atrial fibrillation recurrence following catheter ablation, suggesting a genetic basis for ablation response.
Answers are grounded in this paper and cite their sources.
May inform pre-ablation genetic risk assessment in AF; leaves open prospective validation of ITGA9/SOX5 variants.
Background: PR interval prolongation has recently been shown to associate with advanced left atrial remodeling and atrial fibrillation (AF) recurrence after catheter ablation. While different genome-wide association studies (GWAS) have implicated 13 loci to associate with the PR interval as an AF endophenotype their subsequent associations with AF remodeling and response to catheter ablation are unknown. Here, we perform a gene-based analysis of GWAS data to test the hypothesis that PR interval candidate genes also associate with left atrial remodeling and arrhythmia recurrence following AF catheter ablation. Methods and Results: Samples from 660 patients with paroxysmal (n=370) or persistent AF (n=290) undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using VEGAS (versatile gene-based association study). Among the 13 candidate genes, SLC8A1, MEIS1, ITGA9, SCN5A and SOX5 associated with the PR interval. Of those, ITGA9 and SOX5 were significantly associated with left atrial low voltage areas and left atrial diameter and subsequently with AF recurrence after radiofrequency catheter ablation. Conclusion: This study suggests contributions of ITGA9 and SOX5 to AF remodeling expressed as PR interval prolongation, low voltage areas and left atrial dilatation and subsequently to response to catheter ablation. Future and larger studies are necessary to replicate and apply these findings with the aim of designing AF pathophysiology-based multi-locus risk scores.
No takes yet. Share an insight, caveat, or question.
Husser et al. (2017) conducted a cohort in Atrial Fibrillation (n=660). Genetic variants in PR interval candidate genes (ITGA9 and SOX5) vs. Reference genotypes was evaluated on Atrial fibrillation recurrence between 3 and 12 months after ablation (p=1.0E-06). Genetic variants in ITGA9 and SOX5 were significantly associated with left atrial remodeling (low voltage areas and dilatation) and atrial fibrillation recurrence after catheter ablation.