Key result
Adjusting cardiac output to maintain O2-utilization between 20-25% required cardiac indexes of 3.3-4.4 L/m2/min and led to rapid hemodynamic stabilization in patients with a total artificial heart.
Why the study?
Does adjusting cardiac output based on O2-utilization improve hemodynamic stabilization in patients with a total artificial heart?
Observational
Does adjusting cardiac output based on O2-utilization improve hemodynamic stabilization in patients with a total artificial heart?
Monitoring metabolic parameters such as O2-utilization is crucial for appropriate driver adjustment and hemodynamic stabilization in patients with a total artificial heart.
Answers are grounded in this paper and cite their sources.
May support O2-utilization monitoring for cardiac output adjustment in total artificial heart; leaves open prospective validation.
Control strategies for total artificial heart application have generally been based on experience with healthy animals. Human patients in a bad state of health who have impaired organ functions and who are subjected to intensive care procedures can develop atypical hemodynamic behavior. In these patients, both unstable and hyperstable behavior of the vascular resistance were observed. Therefore, regulation of cardiac output (CO) by pressure parameters only was avoided and CO was adjusted to obtain an appropriate O2-utilization (O2U). Intending to keep the O2U within ranges of 20-25%, we obtained cardiac indexes between 3.3 and 4.4 L/m2/min (CO 6-8 L/min), which is higher than other cardiac indexes reported. A CO of 10.5 L/min was even necessary to obtain an O2U of 30% in a septic patient. This strategy caused a stable driving management and led to a rapid hemodynamic stabilization and general improvement of the patients' condition. Results indicate that it is also very important to monitor metabolic parameters for appropriate driver adjustment as well, especially in the early postoperative phase, and that O2-U is a sensitive and useful parameter for this purpose.
No takes yet. Share an insight, caveat, or question.
Schima et al. (1989) conducted an observational in Total artificial heart application. Regulation of cardiac output based on O2-utilization vs. Regulation by pressure parameters only was evaluated on Hemodynamic stabilization and O2-utilization. Adjusting cardiac output to maintain O2-utilization between 20-25% required cardiac indexes of 3.3-4.4 L/m2/min and led to rapid hemodynamic stabilization in patients with a total artificial heart.
Synapse has enriched 10 related papers. Consider them for comparative context: