Key result
Pump flows delivering oxygen >13 cc/min/kg maintained SvO2 at ~25% without increasing blood lactate, whereas lower flows dropped SvO2 to 10-15% and increased lactate.
Why the study?
Does continuous in-line monitoring of oxygen delivery and SvO2 reflect circulatory status and oxygen debt in biventricular bypass animals during exercise?
Does continuous in-line monitoring of oxygen delivery and SvO2 reflect circulatory status and oxygen debt in biventricular bypass animals during exercise?
Continuous monitoring of mixed venous oxygen saturation is a useful indicator of circulatory status and oxygen debt, potentially guiding artificial heart output control.
Answers are grounded in this paper and cite their sources.
May inform artificial heart output via SvO2 thresholds in animal models; hypothesis-generating for clinical circulatory monitoring.
In order to evaluate the pump output control based on the oxygen delivery to peripheral tissues, arterial and mixed venous hemoglobin content ([Hb]) and oxygen saturation (SO2) were continuously monitored in three biventricular bypass animals (3-, 6-, and 40-day experiments) with fibrillating ventricles. The specially developed oxygen sensors were mounted in the outflow ports of the artificial hearts to measure [Hb] and SO2. One animal was exercised on the treadmill at 2.0 mile/h for 15 min with pump flows fixed to deliver oxygen of (a) above 13 cc/min/kg, (b) 10, and (c) 9. In (a), the mixed venous saturation (SvO2) dropped to approximately 25% with no increase in the blood lactate level. In (b) and (c), the SvO2 decreased to approximately 10-15% with increase in blood lactate levels from 4 to 10-30 mg/dl. Also, the recovery of the SvO2 in these groups following the termination of the exercise was slower in comparison to (a). The lower limit of the SvO2 level that would create oxygen debt situation in the peripheral tissues was approximately 25-30% for the exercise of 2.0 mile/h. The SvO2 reflects changes in respiratory status, pump output, hemoglobin level, and metabolism, and is thus a useful indicator to diagnose quickly the circulatory status as well as possibly to control the artificial heart output.
No takes yet. Share an insight, caveat, or question.
Takatani et al. (1990) studied Biventricular bypass with fibrillating ventricles (n=3). Pump flows fixed to deliver different oxygen levels was evaluated on Mixed venous saturation (SvO2) and blood lactate level. Pump flows delivering oxygen >13 cc/min/kg maintained SvO2 at ~25% without increasing blood lactate, whereas lower flows dropped SvO2 to 10-15% and increased lactate.