Why the study?
Does varying coronary blood flow alter myocardial oxygen consumption in the nonworking dog heart?
Population
23 dog heart experiments with empty ventricles performing no external work
Comparison
Varying coronary blood flow and myocardial O2… vs Different levels of CBF
Design
Preclinical
Authors
Loading...
Should not inform clinical practice; leaves open whether coronary flow modulates MVO2 in working human hearts.
Does varying coronary blood flow alter myocardial oxygen consumption in the nonworking dog heart?
In the nonworking dog heart, myocardial oxygen consumption is directly dependent on coronary blood flow, except when oxygen delivery greatly exceeds demand.
Kahler et al. (1963) studied this question.