Key result
Mitral pannus removal using a minimal access approach was performed in a 64-year-old woman presenting with a transient ischemic attack.
Case Report (n=1)
A minimal access approach can be utilized for the removal of mitral pannus in patients with prior mechanical mitral valve replacement presenting with embolic events.
Answers are grounded in this paper and cite their sources.
Supports feasibility of minimal-access mitral pannus removal after mechanical valve replacement; leaves open comparative efficacy and safety versus sternotomy.
A 64-year-old woman had a mitral valve repair 10 years previously and subsequently had her mitral valve replaced for recurrence of severe mitral regurgitation with a 29-mm St Jude's bileaflet mechanical prosthesis at another institution 5 years ago. She presented to our department following a recent transient ischaemic attack and an echogenic lesion was picked up on the sewing ring of her mitral prosthesis (figure 1A, see online supplementary video 1). Figure 1 (A) Transoesophageal echocardiography. White arrow shows the pannus localised on …
No takes yet. Share an insight, caveat, or question.
Rose et al. (2013) conducted a case report in Mitral pannus (n=1). Mitral pannus removal using a minimal access approach was evaluated. Mitral pannus removal using a minimal access approach was performed in a 64-year-old woman presenting with a transient ischemic attack.