High quality factor 1.3 GHz 9-cell superconducting radio frequency (SRF) cavity cryomodule is the core technology of the international advanced accelerator. China’s first high-quality factor 1.3 GHz 9-cell SRF cavity cryomodule was developed, assembled and tested at the Institute of High Energy Physics (IHEP), Chinese Academy of Sciences for the Dalian Advanced Light Source (DALS) and Circular Electron Positron Collider (CEPC) R&D. The 9-cell cavities in the cryomodule achieved a high average intrinsic quality factor ( Q 0 ) of 3.8 × 10 10 at 16 MV/m and 3.6 × 10 10 at 21 MV/m in the horizontal test. With such high specifications, the SRF cavity system has corresponding requirements for the cryogenic system. Key criteria for stable and reliable operation include a dependable cryogenic refrigeration system and process design, good thermal insulation, pressure control, temperature uniformity, and quench protection, etc. IHEP has successfully completed cryogenic testing development of the first 1.3 GHz 9-cell SRF prototype cryomodule. The whole cooldown period was 74 h, and the automatic cooldown was completed. The successful development and implementation of the 1.3 GHz superconducting cryomodule cryogenic system will provide a stable and reliable test environment for advanced superconducting cavity cryogenic testing, which will be critical in promoting the further development of the Free Electron Laser (FEL) and CEPC projects.
No takes yet. Share an insight, caveat, or question.
Pan et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: