Key result
Proximal optimization technique did not result in a favorable trend in composite bifurcation stent failure compared to kissing balloon technique (29% vs 26% before side branch dilation).
Why the study?
POT is recommended for optimal stent expansion and side branch wiring, but its effect on coronary bifurcation stent failure compared with KBT in crossover stenting required investigation.
Does proximal optimization technique (POT) reduce coronary bifurcation stent failure in patients treated with crossover stenting compared to kissing balloon technique (KBT)?
RCT (n=120)
randomized
Yes
Does proximal optimization technique (POT) reduce coronary bifurcation stent failure in patients treated with crossover stenting compared to kissing balloon technique (KBT)?
Absolute Event Rate: 29% vs 26%
In patients undergoing crossover stenting for coronary bifurcations, the proximal optimization technique did not reduce OCT-defined stent failure compared to the kissing balloon technique.
POT does not reduce bifurcation stent failure versus KBT; leaves open optimal optimization strategy in crossover stenting.
OBJECTIVE: We investigated the effect of proximal optimization technique (POT) on coronary bifurcation stent failure (BSF) in cross-over stenting by comparing with the kissing balloon technique (KBT) in a multicenter randomized PROPOT trial. BACKGROUND: POT is recommended due to increased certainty for optimal stent expansion and side branch (SB) wiring. METHODS: We randomized 120 patients treated with crossover stenting into the POT group, which was followed by SB dilation (SBD), and the KBT group. Finally, 52 and 57 patients were analyzed by optical coherence tomography before SBD and at the final procedure, respectively. Composite BSF was defined as a maximal malapposition distance of >400 μm, or malapposed and SB-jailed strut rates of >5.95% and >21.4%, respectively. RESULTS: Composite BSF before SBD in the POT and KBT groups was observed in 29% and 26% of patients, respectively. In the POT group, differences in stent volumetric index between the proximal and distal bifurcation (odds ratio [OR] 60.35, 95% confidential interval [CI] 0.13-0.93, p = 0.036) and between the proximal bifurcation and bifurcation core (OR: 3.68, 95% CI: 1.01-13.40, p = 0.048) were identified as independent risk factors. Composite BSF at final in 27% and 32%, and unplanned additional procedures in 38% and 25% were observed, respectively. Composite BSF before SBD was a risk factor for the former (OR: 6.33, 95% CI: 1.10-36.50, p = 0.039) and the latter (OR: 6.43, 95% CI: 1.25-33.10, p = 0.026) in the POT group. CONCLUSION: POT did not result in a favorable trend in BSF. Insufficient expansion of the bifurcation core after POT was associated with BSF.
No takes yet. Share an insight, caveat, or question.
Murasato et al. (2022) conducted an RCT in coronary bifurcation stent failure in cross-over stenting (n=120). Proximal optimization technique (POT) vs. Kissing balloon technique (KBT) was evaluated on Composite bifurcation stent failure before side branch dilation. Proximal optimization technique did not result in a favorable trend in composite bifurcation stent failure compared to kissing balloon technique (29% vs 26% before side branch dilation).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: