Answers are grounded in this paper and cite their sources.
For nearly 4 years, our surgical center has used cut Weck-Cel® pledgets (Medtronic Solan) soaked in a mydriatic, antibiotic, nonsteroidal antiinflammatory, and anesthetic cocktail similar to that originally described by Gills (J. Gills, MD, “Special Delivery: Medications for Cataract Surgery,” presented at the ASCRS Symposium on Cataract, IOL and Refractive Surgery, Boston, Massachusetts, USA, May 2000) and more recently by Ong-Tone.1 My technique has evolved somewhat, as the following case illustrates. In January 2001, routine cataract surgery was performed in a patient's left eye, followed by refractive lens exchange in the right eye 1 month later. A small wick (4.0 mm long, as described by Ong-Tone) soaked in the preoperative cocktail was placed beneath the patient's upper eyelid in both cases. Surgery was uneventful, and the patient recovered 20/20 uncorrected visual acuity by the first day in the left eye and by the seventh day in the right eye. The patient had intermittent complaints of a foreign-body sensation, epiphora, and light sensitivity in both eyes, worse in the left eye than in the right eye. The symptoms improved with lubricant drops but did not resolve completely. Evaluation, including upper eyelid eversion, following persistent complaints did not reveal ocular or adenexal foreign bodies. Mild superficial punctate keratitis was consistently noted inferiorly in both eyes, with concomitant interpalpebral conjunctival staining with fluorescein. The patient was sent for a second opinion, but no new information was gathered. Temporary punctal occlusion improved the symptoms. Eighteen months after the procedure, the patient returned holding a small dark object, stating, “This thing fell out of my eye, and my eye finally feels better.” Although the patient was pleased with the improvement in her symptoms, she was distraught that the symptoms persisted for 1 year and that I, the surgeon, caused the symptoms by “leaving a sponge in the eye during cataract surgery.” Since the wick delivery method was initiated, our standard practice has been to have the preoperative nurses place the wick in the fornix of the eye and the circulating nurse in the operating room remove the wick. The surgeon is to be notified if the wick is not located. With our technique, the solution is prepared in the sterile container by the preoperative nurses the day before surgery, with equal amounts of the medications. The solution is placed in the refrigerator. Approximately 7.0 mm long by 3.0 mm wide segments (somewhat longer than the 4.0 mm long wicks described by Ong-Tone1) cut from a Merocel® instrument wipe (Medtronic Solan) are placed in the sterile solution the day of surgery. Forty-five minutes preoperatively, 2 drops of proparacaine 0.5% are administered to the patient's eye and the wick is placed in the eye's lower outer fornix. The patient is instructed to close the eyes. Occasionally, extra mydriatic drops are needed to achieve maximum pupil dilation. Two major modifications of our original technique were developed to decrease the risk for wick retention: (1) using larger wicks and (2) placing the wick in the inferior fornix. Occasionally, however, a wick is missing. It should be difficult for a 7.0 mm wick placed in the lower fornix to become hidden in the upper fornix, which is difficult to search. If not located, it is suspected that the wick has fallen. We have not resorted to taping the lid shut as described by Ong-Tone1 as this precludes the preoperative nursing staff from evaluating the pupil's dilation status. Additionally, it is easier for the nursing staff to place the wick in and remove it from the inferior fornix, minimizing the possibility of iatrogenic corneal abrasions. The major benefits of the wick delivery system are improved drug delivery, decreased corneal toxicity, improved patient comfort, and a simplified process for preoperative staff. However, we need a better wick. The preferred design would be a 4.0 mm microsurgical sponge with a string attached (ie, an ocular lead line). The string could be taped to the lower lid while the sponge is still well positioned in the lower fornix. Wick retention would be a thing of the past. I hope the industry heeds the call. Jonathan M.
No takes yet. Share an insight, caveat, or question.
Jonathan M. Davidorf (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: