Key result
Laser Doppler perfusion monitoring with acetylcholine exhibited less day-to-day variability (within-subject SD/GM = 0.52) than post-occlusive reactivity (0.83), requiring smaller sample sizes.
Observational (n=24)
Acetylcholine iontophoresis with laser Doppler perfusion monitoring provides the most repeatable measure of microvascular reactivity, requiring the smallest sample sizes for longitudinal studies.
Supports acetylcholine laser Doppler for microvascular studies to minimize sample sizes; leaves open prospective validation before wider adoption.
OBJECTIVE: An awareness of the repeatability of biological measures is required to properly design and calculate sample sizes for longitudinal interventional studies. We investigated the day-to-day repeatability of measures of systemic microvascular reactivity using laser Doppler perfusion monitoring. METHODS: We performed laser Doppler perfusion monitoring in combination with skin iontophoresis using acetylcholine and sodium nitroprusside as well as post-occlusive reactive and thermal hyperemia twice within two weeks. The repeatability was assessed by calculating the within-subject standard deviations, limits of agreement, typical errors and intra-class correlation coefficients between days 1 and 2. The ratio of the within-subject standard deviation to the mean values obtained on days 1 and 2 (within-subject standard deviation/GM) was used to determine the condition with the best repeatability. RESULTS: Twenty-four healthy subjects, aged 24.6 ± 3.8 years, were recruited. The area under the curve of the vasodilatory response to post-occlusive reactivity showed marked variability (within-subject standard deviation/GM = 0.83), while the area under the curve for acetylcholine exhibited less variability (within-subject standard deviation/ GM = 0.52) and was comparable to the responses to sodium nitroprusside and thermal treatment (within-subject standard deviations/GM of 0.67 and 0.56, respectively). The area under the blood flow/time curve for vasodilation during acetylcholine administration required the smallest sample sizes, the area under the blood flow/time curve during post-occlusive reactivity required the largest sample sizes, and the area under the blood flow/time curves of vasodilation induced by sodium nitroprusside and thermal treatment required intermediate sizes. CONCLUSIONS: In view of the importance of random error related to the day-to-day repeatability of laser Doppler perfusion monitoring, we propose an original and robust statistical methodology for use in designing prospective clinical studies.
No takes yet. Share an insight, caveat, or question.
Tibiriçá et al. (2011) conducted an observational in healthy (n=24). Laser Doppler perfusion monitoring was evaluated on Day-to-day repeatability (within-subject standard deviation/GM). Laser Doppler perfusion monitoring with acetylcholine exhibited less day-to-day variability (within-subject SD/GM = 0.52) than post-occlusive reactivity (0.83), requiring smaller sample sizes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: