Key result
A fully autonomous preload-sensitive control algorithm for implantable rotary blood pumps demonstrated robust stability across a wide range of physiological variables in computer simulations.
A novel fully autonomous preload-sensitive control algorithm for implantable rotary blood pumps demonstrated robust stability in computer simulations, paving the way for further in vitro and in vivo testing.
Answers are grounded in this paper and cite their sources.
Should not change rotary blood pump practice; leaves open translation of autonomous algorithms pending in vivo validation.
A pulsatility-based control algorithm with a self-adapting pulsatility reference value is proposed for an implantable rotary blood pump and is to be tested in computer simulations. The only input signal is the pressure difference across the pump, which is deduced from measurements of the pump's magnetic bearing. A pulsatility index (PI) is calculated as the mean absolute deviation from the mean pressure difference. As a second characteristic, the gradient of the PI with respect to the pump speed is derived. This pulsatility gradient (GPI) is used as the controlled variable to adjust the operating point of the pump when physiological variables such as the systemic arterial pressure, left ventricular contractility, or heart rate change. Depending on the selected mode of operation, the controller is either a linear controller or an extremum-seeking controller. A supervisory mechanism monitors the state of the system and projects the system into the region of convergence when necessary. The controller of the GPI continuously adjusts the reference value for PI. An underlying robust linear controller regulates the PI to the reference value in order to take into account changes in pulmonary venous return. As a means of reacting to sudden changes in the venous return, a suction detection mechanism was included. The control system is robustly stable within a wide range of physiological variables. All the clinician needs to do is to select between the two operating modes. No other adjustments are required. The algorithm showed promising results which encourage further testing in vitro and in vivo.
No takes yet. Share an insight, caveat, or question.
Arndt et al. (2010) studied Heart failure requiring implantable rotary blood pump. Pulsatility-based control algorithm with a self-adapting pulsatility reference value was evaluated on Robust stability within a wide range of physiological variables. A fully autonomous preload-sensitive control algorithm for implantable rotary blood pumps demonstrated robust stability across a wide range of physiological variables in computer simulations.