Key result
Using a self-contained breathing apparatus during moderate-intensity exercise decreased LV preload and increased LV contractility (p < 0.05) compared to free breathing, without reducing stroke area.
Why the study?
Does the use of a self-contained breathing apparatus affect left-ventricular function at rest and during graded exercise in healthy male volunteers?
Does the use of a self-contained breathing apparatus affect left-ventricular function at rest and during graded exercise in healthy male volunteers?
p-value: p=<0.05
SCBA use during exercise decreases LV preload but maintains stroke area through increased LV contractility and decreased end-systolic wall stress.
SCBA may alter LV mechanics during exercise in healthy adults; hypothesis-generating and should not yet change practice.
The purpose of this study was to examine the effects of the self-contained breathing apparatus (SCBA) on left-ventricular (LV) function at rest and during mild- to moderate-intensity exercise, using 2-dimensional echocardiography. Twenty-three healthy male volunteers exercised on a stair-climber at work rates equivalent to 50%, 60%, 70%, and 80% of peak oxygen consumption. Esophageal pressure LV diastolic and systolic cavity areas, and myocardial areas were acquired during the final minute of each stage of exercise. As expected, the esophageal pressure response during SCBA breathing revealed significantly lower (more negative) inspiratory pressures and higher (more positive) expiratory pressures and, consequently, higher pressure swings, than free breathing (FB). End-diastolic cavity area (EDCA) and end-systolic cavity area (ESCA) were lower with the SCBA than with FB. LV contractility was higher (p < 0.05) with the SCBA, which can partially be explained by decreases in end-systolic wall stress. Therefore, the SCBA was found to decrease LV preload during moderate-intensity exercise, but did not negatively affect stroke area because of a similar reduction in ESCA.
No takes yet. Share an insight, caveat, or question.
Mayne et al. (2009) studied Healthy (n=23). Self-contained breathing apparatus (SCBA) vs. Free breathing (FB) was evaluated on Left-ventricular (LV) function at rest and during mild- to moderate-intensity exercise (p=<0.05). Using a self-contained breathing apparatus during moderate-intensity exercise decreased LV preload and increased LV contractility (p < 0.05) compared to free breathing, without reducing stroke area.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: