Key result
During sustained exercise, use of a self-contained breathing apparatus significantly reduced left ventricular end-diastolic cavity area and stroke area compared to a low resistance valve (P<0.05).
Why the study?
Does a self-contained breathing apparatus reduce left-ventricular function during strenuous exercise in healthy men?
Does a self-contained breathing apparatus reduce left-ventricular function during strenuous exercise in healthy men?
p-value: p=< 0.05
During strenuous exercise and heat stress, the use of a self-contained breathing apparatus increases intrathoracic pressure, leading to significant reductions in left ventricular preload and stroke area.
SCBA use may reduce LV preload during strenuous exercise; leaves open effects on occupational performance or safety.
The purpose of this study was to investigate left-ventricular function during strenuous exercise with the self-contained breathing apparatus (SCBA). With the use of two-dimensional echocardiography, images of the left ventricle (LV) were acquired during sustained exercise (3 x 10 min) under two conditions: 1) SCBA, or 2) low resistance breathing valve. Twenty healthy men volunteered for the study, and in each condition subjects wore fire protective equipment. Heart rate, systolic blood pressure, cavity areas during systole and diastole (ESCA and EDCA, respectively), esophageal pressure, ventilation rate, oxygen consumption, perceived physical, thermal and respiratory distress, and core temperature were measured at regular intervals. Urine specific gravity (<1.020 g/ml) and hematological variables were used to infer hydration status. All subjects began both trials in a euhydrated state. No differences were found between conditions for heart rate, systolic blood pressure, ventilation rate, oxygen consumption, perceived distress, or any hematological variables. Peak expiratory esophageal pressure was always higher (P < 0.05), while EDCA and stroke area (SA) were significantly lower (P < 0.05) with the SCBA. ESCA, end-systolic transmural pressure (ESTMP), and LV contractility (ESTMP/ESCA) were similar between conditions. Sustained exercise with fire protective equipment resulted in significant reductions in EDCA, ESCA, and SA from the start of exercise, which was associated with a 6.3 +/- 0.8% reduction in plasma volume, an increase in core temperature (37.0 +/- 0.4 to 38.8 +/- 0.3 degrees C), and a significant increase in heart rate (146.9 +/- 2.1 to 181.7 +/- 2.4 beats/min) throughout exercise. The results from this study support research by others showing that increased intrathoracic pressure reduces LV preload (EDCA); however, the novelty of the present study is that when venous return is compromised by sustained exercise and heat stress, SA cannot be maintained.
No takes yet. Share an insight, caveat, or question.
Nelson et al. (2008) studied Healthy (n=20). Self-contained breathing apparatus (SCBA) vs. Low resistance breathing valve was evaluated on Left-ventricular function (end-diastolic cavity area and stroke area) (p=< 0.05). During sustained exercise, use of a self-contained breathing apparatus significantly reduced left ventricular end-diastolic cavity area and stroke area compared to a low resistance valve (P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: