Key result
Morphometric analysis of the human coronary vasculature revealed asymmetrical branching, indicating it should be modeled with self-similar asymmetrical tree-like systems.
Answers are grounded in this paper and cite their sources.
Based on morphometric data, we calculate the structural parameters of the coronary vasculature as an optimal branching bed. We show (i) significant correlations between the diameters of the larger daughter and the parent vessel and between the diameter of the smaller daughter vessel and the asymmetry coefficient; (ii) differences in the structural parameters for two types of artery that deliver and distribute blood in the cardiac muscle; and (iii) the length-diameter relationships for different arteries. The coronary vasculature is characterized by asymmetrical branching and thus should be modeled with self-similar asymmetrical tree-like systems.
No takes yet. Share an insight, caveat, or question.
Zenin et al. (2007) studied Human coronary vasculature. Morphometric analysis was evaluated on Structural parameters of the coronary vasculature. Morphometric analysis of the human coronary vasculature revealed asymmetrical branching, indicating it should be modeled with self-similar asymmetrical tree-like systems.