In this paper, faults associated with the rotor of an induction machine are considered. More specifically, effects of adjacent and nonadjacent bar breakages on rotor fault diagnostics in squirrel-cage induction machines are studied. It is shown that some nonadjacent bar breakages may result in the masking of the commonly used fault indices and, hence, may lead to a possible misdiagnosis of the machine. A discussion of the possible scenarios of these breakages as well as some conclusions regarding the types of squirrel-cage induction machines (number of poles, number of squirrel-cage bars, etc.) that may be more prone to these nonadjacent types of failures are presented. This discussion is supported through both simulation and experimental results. It is also shown that secondary fault effects can be used to diagnose such nonadjacent bar breakages.
No takes yet. Share an insight, caveat, or question.
Sizov et al. (2009) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: