Answers are grounded in this paper and cite their sources.
The theory and calibration procedure for a cylindrical falling body viscometer is presented. Experimental viscosity data are given for liquid methane from −150°C. to the critical point and for liquid propane from −185° to +90°C. The maximum experimental error for methane data is ±8% and for propane data ±5%.
No takes yet. Share an insight, caveat, or question.
Swift et al. (1959) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: