Key result
Induced blood oxidation parameters did not significantly differ between patients undergoing on-pump versus off-pump coronary artery bypass grafting at 10 days and 6 months post-surgery.
Why the study?
Artificial circulation in surgical myocardial revascularization is a key factor in oxidative stress and systemic inflammatory response, prompting evaluation of induced blood oxidation dynamics in on-pump versus off-pump surgery.
Does off-pump coronary artery bypass surgery compared to on-pump surgery improve induced blood oxidation parameters and clinical outcomes in patients with coronary heart disease?
Observational (n=88)
Open-label
No
Does off-pump coronary artery bypass surgery compared to on-pump surgery improve induced blood oxidation parameters and clinical outcomes in patients with coronary heart disease?
Induced blood oxidation parameters do not depend on the method of revascularization (on-pump vs off-pump) and changes are transient in the early postoperative period.
Small observational study describes oxidation parameters in on- vs off-pump CABG; leaves open impact on outcomes and optimal strategy.
Background: The use of artificial circulation in surgical myocardial revascularization is one of the key pathogenetic factors in the development of the oxidative stress and systemic inflammatory response in the postoperative period. Aims: the purpose of the study was to describe the dynamics of the induced blood oxidation parameters during coronary artery bypass surgery in the conditions of artificial circulation and on the working heart. Methods: The study included 64 patients who underwent coronary bypass surgery, with 31 (48.4%) on-pump patients and 33 (51.6%) off-pump patients. The oxidative stress simulations were conducted under the in vitro conditions. The blood oxidation-induced values were studied using a biological oxygen monitor. Results: In patients with coronary heart disease, regardless of the choice of the revascularization method (on-pump / off-pump), we observed statistically significantly (p 0.05) higher initial and maximum blood oxidation rates, the oxidative activity factor, and a shorter initiation period than those in healthy volunteers. No significant differences were found by the inter-group comparison analysis both 10 days and 6 months post-surgery. Conclusion: The indicators of induced blood oxidation do not depend on the method of revascularization during coronary bypass grafting (artificial circulation or a working heart). The changes in the parameters indicating activation of the oxidative and antioxidant blood systems may be transient by their nature and occur in the early postoperative period.
No takes yet. Share an insight, caveat, or question.
Shereshneva et al. (2022) conducted an observational in Coronary heart disease (n=88). On-pump coronary artery bypass grafting vs. Off-pump coronary artery bypass grafting was evaluated on Overall mortality, cardiovascular mortality, and readmission within 12 months. Induced blood oxidation parameters did not significantly differ between patients undergoing on-pump versus off-pump coronary artery bypass grafting at 10 days and 6 months post-surgery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: