Key result
The TMEM16F channel showed a higher permeability for Na+ (PNa/PCl 3.7) in inside-out experiments compared to a slight preference for Cl- (PNa/PCl ~0.5) in whole-cell recordings.
Why the study?
Several studies have reported conflicting results regarding the ion selectivity of the TMEM16F-mediated current.
Absolute Event Rate: 3.7% vs 0.5%
The ion selectivity and activation kinetics of the TMEM16F channel are highly dependent on the electrophysiological recording configuration used.
Recording configuration dictates TMEM16F selectivity and activation speed; leaves open its precise ion role in coagulation and infection.
TMEM16F is involved in several physiological processes, such as blood coagulation, bone development and virus infections. This protein acts both as a Ca2+-dependent phospholipid scramblase and a Ca2+-activated ion channel but several studies have reported conflicting results about the ion selectivity of the TMEM16F-mediated current. Here, we have performed a detailed side-by-side comparison of the ion selectivity of TMEM16F using the whole-cell and inside-out excised patch configurations to directly compare the results. In inside-out configuration, Ca2+-dependent activation was fast and the TMEM16F-mediated current was activated in a few milliseconds, while in whole-cell recordings full activation required several minutes. We determined the relative permeability between Na+ and Cl¯ (PNa/PCl) using the dilution method in both configurations. The TMEM16F-mediated current was highly nonselective, but there were differences depending on the configuration of the recordings. In whole-cell recordings, PNa/PCl was approximately 0.5, indicating a slight preference for Cl¯ permeation. In contrast, in inside-out experiments the TMEM16F channel showed a higher permeability for Na+ with PNa/PCl reaching 3.7. Our results demonstrate that the time dependence of Ca2+ activation and the ion selectivity of TMEM16F depend on the recording configuration.
No takes yet. Share an insight, caveat, or question.
Stabilini et al. (2021) studied this question. Inside-out excised patch configuration vs. Whole-cell configuration was evaluated on Relative permeability between Na+ and Cl- (PNa/PCl). The TMEM16F channel showed a higher permeability for Na+ (PNa/PCl 3.7) in inside-out experiments compared to a slight preference for Cl- (PNa/PCl ~0.5) in whole-cell recordings.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: