The authors describe the advances made in high-power ignitron switching capabilities in a comparison study between conventional size D and size E tubes, demountable experimental tubes, and the new NL-9000 (Richardson Electronics). The authors discuss the differences in tube design and the associated peak current and charge transfer capabilities and lifetime expectancies. The critical design criteria are the anode shape and placement in order to control the plasma and prevent prefires. Tube failure modes and recent studies on alternate ignitor schemes are presented. In addition, results of plasma diagnostics performed on a demountable ignitron with optical access to the discharge plasma are shown. Time-resolved images of the interference patterns from an optical Mach-Zehnder interferometer were recorded with a mechanical high-speed camera and evaluated with the help of image processing.>
No takes yet. Share an insight, caveat, or question.
Loree et al. (1991) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: