Key result
Normalized pulse wave transit time measurement correlated well with the degree of internal carotid artery stenosis estimated by arteriography.
Why the study?
Does pulse wave transit time measurement correlate with the degree of carotid artery stenosis estimated by arteriography?
Observational (n=24)
Does pulse wave transit time measurement correlate with the degree of carotid artery stenosis estimated by arteriography?
Pulse wave transit time measurement provides a simple, reproducible, non-invasive technique for diagnosing varying degrees of carotid artery stenosis.
Answers are grounded in this paper and cite their sources.
May support non-invasive carotid stenosis assessment; leaves open need for prospective validation before clinical adoption.
A prospective study has been undertaken on 24 patients to establish the relationship between the degree of internal carotid artery stenosis, as estimated by arteriography, and the pulse wave transit time in the carotid artery. The technique involves the simultaneous use of two continuous wave Doppler velocimeters, one on the carotid and one on the supraorbital artery, to measure the flow waves and hence deduce the pulse wave transit times. The measured transit times varied from 17 to 124 ms with a beat-to-beat variation of 11 per cent. The absolute transit time in any segment correlated moderately well with the estimated degree of stenosis (r = 0.68, P less than 0.001). However, normalization of the transit times, to correct for the effects of blood pressure and age, produced on improved correlation between the variables (r = 0.8, P less than 0.001). Normalization was achieved by dividing the common carotid to supraorbital transit time by the shortest transit time found between the common carotid and either the superficial temporal or brachial arteries. Significant differences in the normalized transit times were found between arteries that were diametrically stenosed by more than 50 per cent, by between 21 and 50 per cent and by 20 per cent or below. It is concluded that pulse wave transit time measurement can provide a simple and reproducible non-invasive technique for the diagnosis of varying degrees of carotid artery stenosis.
No takes yet. Share an insight, caveat, or question.
Horrocks et al. (1979) conducted an observational in Carotid artery stenosis (n=24). Pulse wave transit time measurement vs. Arteriography was evaluated on Correlation between normalized transit times and estimated degree of stenosis (r = 0.8, p=<0.001). Normalized pulse wave transit time measurement correlated well with the degree of internal carotid artery stenosis estimated by arteriography.
Synapse has enriched 10 related papers. Consider them for comparative context: