Key result
Opacity pulse propagation and thermometry detect >50% carotid stenosis with ~83% sensitivity.
Why the study?
The clinical utility of opacity pulse propagation times and skin thermometry in detecting carotid occlusive vascular disease compared to angiography was evaluated.
Does opacity pulse propagation measurement and thermometry accurately detect carotid occlusive vascular disease compared to four-vessel angiography in patients evaluated for cerebrovascular disease?
Observational (n=46)
Does opacity pulse propagation measurement and thermometry accurately detect carotid occlusive vascular disease compared to four-vessel angiography in patients evaluated for cerebrovascular disease?
The combination of opacity pulse propagation measurement and thermometry is a useful non-invasive screening tool for detecting carotid occlusive disease.
Answers are grounded in this paper and cite their sources.
May support non-invasive screening for carotid occlusive disease; leaves open prospective validation in larger cohorts.
A correlative study of four-vessel angiography with measurements of opacity pulse propagation times and skin temperatures over the medial supraorbital areas of the forehead was carried out in 46 patients. Differences in propagation times of greater than 12 milliseconds and/or in thermometric measurements of 1 °F or more were always associated with angiographically demonstrable carotid occlusive disease. In patients with positive angiographical findings, prolongation of pulse propagation time was associated with lower skin temperature when the latter occurred. Test results indicated abnormality in six of seven patients with bilateral carotid occlusive disease. By these methods, unilateral occlusive lesions of 30% to 50% of the vascular lumen were detected in three of five instances where such lesions occurred; occlusive lesions greater than this degree were detected in 15 of 18 patients. The tests identified as "normal" 18 of 23 patients whose four-vessel angiograms were either totally unremarkable or showed lesions compromising less than 30% of the carotid lumen. Combination of these screening tests is more useful than either test employed alone and may be helpful in clinical evaluation of patients with cerebrovascular disease.
No takes yet. Share an insight, caveat, or question.
Price et al. (1972) conducted an observational in Carotid Occlusive Vascular Disease (n=46). Opacity pulse propagation measurement and thermometry vs. Four-vessel angiography was evaluated on Detection of angiographically demonstrable carotid occlusive disease. Opacity pulse propagation and thermometry detected unilateral carotid occlusive lesions >50% in 15 of 18 patients and correctly identified 18 of 23 normal patients compared to angiography.