Key result
Precise Nitinol stents linked to ~91% higher rate of hemodynamic depression versus Wallstent Elgiloy stents.
Why the study?
Does the type of self-expandable stent (Precise vs Wallstent) affect the incidence of hemodynamic depression and thromboembolism in patients undergoing carotid artery stenting?
Observational (n=87)
No
Does the type of self-expandable stent (Precise vs Wallstent) affect the incidence of hemodynamic depression and thromboembolism in patients undergoing carotid artery stenting?
The use of slotted-tube Nitinol stents (Precise) during carotid artery stenting is associated with a significantly higher risk of postprocedural hemodynamic depression compared to braided Elgiloy stents (Wallstent).
Stent choice may influence postprocedural hemodynamic depression risk; leaves open whether Precise stents increase complications versus Wallstents in carotid stenting.
The rates of hemodynamic depression (HD) and thromboembolism were compared in 95 carotid artery stenting (CAS) procedures performed in 87 patients with severe carotid artery stenosis using self-expandable braided Elgiloy stents (Wallstent) in 52 and slotted-tube Nitinol stents (Precise) in 43 procedures. The blood pressure, pulse rate, and neurological signs were recorded at short intervals during and after CAS. All patients underwent diffusion-weighted magnetic resonance imaging within 5 days after the procedure. The incidences of hypotension, bradycardia, and both were 17.9%, 3.2%, and 11.6%, respectively. The rate of postprocedural HD was 23.1% with Wallstent and 44.2% with Precise; the difference was significant (p = 0.025). No patient manifested major cardiovascular disease after CAS. Diffusion-weighted magnetic resonance imaging revealed thromboembolism after 26.9% and 34.9% of Wallstent and Precise stent placement procedures, respectively; the difference was not significant. The type of self-expandable stent placed may affect the risk of procedural HD in patients undergoing CAS. Postprocedural HD was resolved successfully by the administration of vasopressors and by withholding antihypertensive agents.
No takes yet. Share an insight, caveat, or question.
Nii et al. (2011) conducted an observational in Severe carotid artery stenosis (n=87). Precise stent (slotted-tube Nitinol stent) vs. Wallstent (braided Elgiloy stent) was evaluated on Postprocedural hemodynamic depression (HD) (p=0.025). The use of Precise slotted-tube Nitinol stents during carotid artery stenting was associated with a significantly higher rate of postprocedural hemodynamic depression (44.2%) compared to Wallstent braided Elgiloy stents (23.1%, p=0.025).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: