Answers are grounded in this paper and cite their sources.
A vector-scan Gaussian beam lithography system has been retrofitted with a thermal-field emission electron gun to improve resolution and increase target current density. The design combines a Zr/O/W〈100〉 cathode, three element electrostatic lens, and an octupole stigmator–deflector with the original objective lens and deflection system. Beam voltage is variable up to 25 kV. At high resolution, 1 nA emitted into a gun acceptance semiangle of α0=0.5 mrad is focused to 150 Å at the target with a current density of 500 A/cm2. The current density maximum corresponds to α0=2.2 mrad where a 23 nA, 25 kV probe current is focused to 300 Å with a final convergence angle of 3 mrad at 30-mm working distance. These values imply a current density of 2.6×103 A/cm2 and an effective brightness of 9×107 A/cm2 sr at the target. The conversion is transparent to the original pattern generation–deflection system. This allows the design change to be rapidly incorporated with the existing subsystems. Proximity corrected 750-Å features have been developed.
No takes yet. Share an insight, caveat, or question.
Gesley et al. (1988) studied this question.