This is the authors' abstract. We don't add key points for this paper.
In this work, we present a novel, sensitive, easy-to-fabricate, flexible amperometric sensor constituted by screen-printed silver (Ag) electrodes functionalized with a copper (Cu) film electrodeposited on top of a spray coated network of single-walled carbon nanotubes (SWCNTs). The Cu/SWCNTs/Ag electrode showed excellent catalytic activity towards the electro-reduction of nitrate ions at neutral pH with a significant increase in cathodic peak currents in comparison with the electrode without SWCNTs (Cu/Ag). The developed Cu/SWCNTs/Ag sensor showed a wide linear detection range from 0.5 μM to 6.0 mM (0.31 mg/l to 372.02 mg/l) with good sensitivity (18.39 μA/mM) and a calculated limit of detection (LOD) of 0.166 nM (10.29 μg/l). It also showed a good selectivity (maximum standard deviation (SD) was 3.25 μA) towards different interfering ions (Fe2+, Na+, Cu2+, SO42-, CH3COO-, Cl-, NO2- and HCO3-), as well as good reproducibility, mechanical durability, time and temperature stability. In real sample analysis (tap and river water), the sensor exhibited good agreement with the compared outcome of high-performance liquid chromatography (HPLC) measurements, proving to be a promising analytical tool for the detection of nitrate in water.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Inam et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: