Key result
Neighboring end-diastolic cineframe selection shows no significant difference in quantitative coronary arterial dimensions.
Why the study?
Does the selection of different cineframes in the end-diastolic phase affect the reproducibility of quantitative coronary arterial dimension measurements?
Observational (n=38)
Does the selection of different cineframes in the end-diastolic phase affect the reproducibility of quantitative coronary arterial dimension measurements?
p-value: p=NS
The selection of a specific cineframe within the end-diastolic phase for quantitative coronary analysis does not significantly affect the reproducibility of obstruction measurements.
Variations in end-diastolic frame selection do not affect QCA reproducibility; supports standardized protocols yet leaves open prospective confirmation.
To quantitatively analyze a coronary arterial segment from a cineangiogram, an end-diastolic or neighboring cineframe is usually selected, such that a possibly existing coronary lesion is visualized optimally, as judged by the cardiologist. However, different cardiologists may select different (although usually neighboring) frames, even when following the same selection criteria. It is also possible that the frames are selected from different cardiac cycles. In this study the effects of such phase shifts on the reproducibility of the quantitative measurements were studied. In a total of 38 consecutive patient films obtained at a filmspeed of 25 frames/sec, the frame 0 demonstrating the severity of a lesion optimally, as judged by a senior cardiologist, the three preceding frames, the three following frames and one frame exactly one cycle prior to or following frame 0 were selected; frame 0 was always chosen in the end-diastolic phase of the cardiac cycle. In each film one coronary arterial segment with a focal lesion was analyzed quantitatively in these eight frames with the Cardiovascular Angiography Analysis System (CAAS). No significant differences were found in the mean difference and the standard deviations of the differences (variabilities) in the obstruction diameter, interpolated reference diameter, percent diameter stenosis, extent of the obstruction and area of atherosclerotic plaque obtained in the various frames with respect to frame 0. Therefore, it may be concluded that the selection of a cineframe for quantitative analysis in the end-diastolic phase of the cardiac cycle is not very critical; in other words, the obstruction measurements are not time-dependent for frames in the end-diastolic phase.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Reiber et al. (1988) conducted an observational in Coronary arterial lesions (n=38). Variations in cineframe selection vs. Optimal frame in end-diastolic phase (Frame 0) was evaluated on Variabilities in obstruction diameter, interpolated reference diameter, percent diameter stenosis, extent of obstruction, and area of atherosclerotic plaque (p=NS). Variations in the selection of neighboring end-diastolic cineframes resulted in no significant differences in quantitative measurements of coronary arterial dimensions.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: