Key result
Frame selection method during quantitative coronary angiographic analysis significantly impacted measurements of stenosis, restenosis, and late lumen loss (best vs. worst, P<0.001).
Why the study?
Does the method of frame selection impact the results of quantitative coronary angiographic analysis after coronary stenting?
Observational (n=39)
Does the method of frame selection impact the results of quantitative coronary angiographic analysis after coronary stenting?
p-value: p=<0.001
Allowing operators to select which frame to analyze during quantitative coronary angiography introduces significant variability and frame bias in measuring acute and late coronary stent outcomes.
Operator frame selection may bias QCA metrics after stenting; leaves open need for standardized protocols in trials.
This study examined the impact of frame selection on the results of quantitative coronary angiographic analysis (QCA). Thirty-nine patients who had stent implantation and a follow-up angiogram 5-7 months later were studied using the CMS Medis QCA system. The acute and follow-up films (n = 39) were read in three different ways to assess the impact of frame selection: frame chosen making the stent appear least narrowed (best); frame chosen making the stent appear most narrowed (worst); and measurement from the mean value from three consecutive end-diastolic frames (core). We measured the mean percent diameter stenosis immediately postintervention and at follow-up, the binary restenosis rate, and the late lumen loss (mm). There was a statistically significant difference in all of these variables when comparing the three methods of frame selection (best vs. worst, P values < 0.001; best or worst vs. core, P values < 0.01). This study demonstrates a marked variability in the results obtained using QCA to measure the acute and late coronary stent outcomes when operators have the ability to select which frame to analyze (frame bias).
No takes yet. Share an insight, caveat, or question.
Fischell et al. (2005) conducted an observational in Coronary stenting (n=39). Frame selection (best, worst, core) vs. Comparison between methods was evaluated on Mean percent diameter stenosis, binary restenosis rate, and late lumen loss (p=<0.001). Frame selection method during quantitative coronary angiographic analysis significantly impacted measurements of stenosis, restenosis, and late lumen loss (best vs. worst, P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: