Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
July 1, 1995HeartOpen Access

Dual chamber pacing: how many patients remain in DDD mode over the long term?

View Full Paper
Ask AI
Bookmark
Share

Key result

DDD pacing is maintained in ~84% of patients at 60 months, with AF driving most reprogramming.

  • n=249

Population

249 patients with DDD pacemakers

Design

Cohort

Follow-up

Mean 32 months (range 1-10 years)

Authors

BIBaharudin IbrahimUniversity of MalayaJSJohn E. SandersonHeart Failure & TransplantBWBarth WrightKansas City University

Discussion

Loading...

Member takes

Overview

Supports long-term DDD retention in most dual-chamber pacemaker recipients; leaves open optimal initial mode selection pending prospective trials.

Study Design

Type

Cohort (n=249)

Multicenter

No

Structured PICO

P
Population
249 patients with DDD pacemakers (predominantly sick sinus syndrome or atrioventricular conduction disease) followed for a mean of 32 months (up to 10 years).
E
Exposure
Dual chamber (DDD) pacing
O
Outcome
Survival of DDD mode over the long term (up to 10 years)

Most patients with dual chamber pacemakers can be successfully maintained in DDD or an alternative atrial pacing mode over the long term, supporting the routine use of dual chamber pacing.

Cite This Study

Ibrahim et al. (1995) conducted a cohort in Sick sinus syndrome and atrioventricular conduction disease requiring pacing (n=249). DDD mode pacing was evaluated on Cumulative survival of DDD mode at 60 months. DDD pacing mode was maintained in 83.5% of patients at 60 months, with atrial fibrillation being the most common reason for reprogramming to an alternative mode.

synapsesocial.com/papers/6aa20734778c15cc5446ecf7https://doi.org/10.1136/hrt.74.1.76
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1<b>DDI Pacing:</b> Indications, Expectations, and Follow‐Up1994 · 7 citations
  2. 2<b>Reasons for Reprogramming Dual Chamber Pacemakers to VVI Mode</b>: A Retrospective Review Using a Computer Database1994 · 30 citations
  3. 3A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing.1982 · 298 citations
  4. 4Apparent Extension of the Atrioventricular Interval Due to Sensor‐Based Algorithm Against Supraventricuiar Tachyarrhythmias1994 · 8 citations
  5. 5Atrial Fibrillation and Embolic Complications in Paced Patients1988 · 48 citations