Key result
PCR-MS detects enterovirus and parvovirus in ~40% of explanted IDCM hearts, correlating strongly with RT-qPCR.
Why the study?
Does PCR-MS accurately detect and semiquantify cardiotropic viruses in explanted heart tissues of adult patients with IDCM compared to RT-qPCR?
Observational (n=31)
Does PCR-MS accurately detect and semiquantify cardiotropic viruses in explanted heart tissues of adult patients with IDCM compared to RT-qPCR?
PCR-MS is a valuable and accurate tool for the rapid detection and semiquantitation of common cardiotropic viruses in explanted heart tissues of patients with idiopathic dilated cardiomyopathy.
Answers are grounded in this paper and cite their sources.
Supports PCR-MS for viral detection in IDCM explants; leaves open prospective validation before clinical adoption.
Viral detection in heart tissues has become a central issue for the diagnosis and exploration of the pathogenesis of idiopathic dilated cardiomyopathy (IDCM). In the present study, common cardiotropic viruses in 67 explanted heart samples of 31 IDCM adult patients were detected and semiquantified by using for the first time a new technology based on PCR assay coupled to electrospray ionization-time of flight mass spectrometry analysis (PCR-MS), with comparison to reference quantitative real-time PCR (RT-qPCR) assay. PCR-MS identified single or mixed enterovirus (EV) and parvovirus B19 (PVB19) infections in 27 (40.2%) of 67 samples, corresponding to 15 (48.3%) of the 31 patients, whereas RT-qPCR identified viral infections in 26 (38.8%) samples, corresponding to 16 (51.6%) of the patients. The PCR-MS results correlated well with EV and PVB19 detection by RT-qPCR (kappa = 0.85 [95% confidence interval {CI}, 0.72 to 1.00] and kappa = 0.82 [95% CI, 0.66 to 0.99], respectively). The levels of EV RNA (median, 550 [range, 178 to 3,200] copies/μg of total extracted nucleic acids) and of PVB19 DNA (median, 486 [range, 80 to 1,157] copies/μg of total extracted nucleic acids) were measured using PCR-MS and correlated with those obtained by RT-qPCR (r(2) = 0.57, P = 0.002 and r(2) = 0.64, P < 0.001 for EV and PVB19, respectively). No viruses other than EV and PVB19 strains were detected using the new PCR-MS technology, which is capable of simultaneously identifying 84 known human viruses in one assay. In conclusion, we identified single or mixed EV and PVB19 cardiac infections as potential causes of IDCM. The PCR-MS analysis appeared to be a valuable tool to rapidly detect and semiquantify common viruses in cardiac tissues and may be of major interest to better understand the role of viruses in unexplained cardiomyopathies.
No takes yet. Share an insight, caveat, or question.
N’Guyen et al. (2013) conducted an observational in Idiopathic dilated cardiomyopathy (IDCM) (n=31). PCR coupled with mass spectrometry analysis (PCR-MS) vs. Quantitative real-time PCR (RT-qPCR) was evaluated on Detection of viral infections in explanted heart samples (kappa 0.85, 95% CI 0.72 to 1.00). PCR coupled with mass spectrometry analysis detected enterovirus and parvovirus B19 in 40.2% of explanted heart samples from IDCM patients, correlating well with RT-qPCR.
Synapse has enriched 10 related papers. Consider them for comparative context: