Key result
Highly specific RT-LAMP-FMDV test achieves ~79% sensitivity on unextracted field samples.
Why the study?
Foot-and-mouth disease is highly contagious, and rapid, early field diagnosis is needed to aid disease control and minimize deleterious economic and welfare impacts.
Does the RT-LAMP-FMDV test accurately detect foot-and-mouth disease virus compared to rRT-PCR in field samples?
Does the RT-LAMP-FMDV test accurately detect foot-and-mouth disease virus compared to rRT-PCR in field samples?
Effect estimate: Sensitivity 79% (95% CI 65-90)
The newly developed RT-LAMP-FMDV test with an internal positive control is a fit-for-purpose herd diagnostic tool for rapid field detection of foot-and-mouth disease.
May aid rapid field herd screening with high specificity; leaves open prospective validation before routine diagnostic adoption.
Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hooved animals. Global outbreaks have highlighted the significant economic, trade, psychosocial and animal welfare impacts that can arise from the detection of disease in previously 'FMD-free' countries. Rapid and early diagnosis provides significant advantages in disease control and minimization of deleterious consequences. We describe the process of further development and validation of a reverse-transcription loop-mediated isothermal amplification foot-and-mouth disease virus (RT-LAMP-FMDV) test, using a published LAMP primer set, for use in the field. An internal positive control (IPC) was designed and introduced for use with the assay to mitigate any intrinsic interference from the unextracted field samples and avoid false negatives. Further modifications were included to improve the speed and operability of the test, for use by non-laboratory trained staff operating under field conditions, with shelf-stable reaction kits which require a minimum of liquid handling skills. Comparison of the assay performance with an established laboratory-based real-time reverse transcriptase PCR (rRT-PCR) test targeting the 3D region of FMD virus (Tetracore Inc) was investigated. LAMP has the potential to complement current laboratory diagnostics, such as rRT-PCR, as a preliminary tool in the investigation of FMD. We describe a strategic approach to validation of the test for use in the field using extracted RNA samples of various serotypes from Thailand and then finally unextracted field samples collected from FMD-suspected animals (primarily oral lesion swabs) from Bhutan and Australia. The statistical approach to validation was performed by Frequentist and Bayesian latent class methods, which both confirmed this new RT-LAMP-FMDV test as fit-for-purpose as a herd diagnostic tool with diagnostic specificity >99% and sensitivity 79% (95% Bayesian credible interval: 65, 90%) on unextracted field samples (oral swabs).
No takes yet. Share an insight, caveat, or question.
Bath et al. (2020) studied Foot-and-mouth disease. RT-LAMP-FMDV test vs. rRT-PCR test was evaluated on Diagnostic sensitivity on unextracted field samples (Sensitivity 79%, 95% CI 65-90). The RT-LAMP-FMDV test demonstrated a diagnostic specificity of >99% and sensitivity of 79% (95% Bayesian credible interval: 65-90%) on unextracted field samples.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: