Key result
In patients treated with warfarin for bioprosthetic valve thrombosis, recovery was faster in mitral than aortic and tricuspid positions.
Why the study?
How early abnormal gradients can be detected prior to bioprosthetic valve thrombosis diagnosis and how fast they normalise with anticoagulant therapy were unknown.
Does the time to recovery of bioprosthetic valve thrombosis gradients with warfarin therapy vary by valve position and type?
Cohort (n=77)
Does the time to recovery of bioprosthetic valve thrombosis gradients with warfarin therapy vary by valve position and type?
Echocardiographic gradients increase months before clinical BPVT diagnosis, and recovery with warfarin is faster in mitral and surgical porcine aortic valves compared to tricuspid and surgical pericardial aortic valves.
Answers are grounded in this paper and cite their sources.
Early gradient rises may enable earlier BPVT detection; leaves open optimal anticoagulation duration by valve position and type.
OBJECTIVE: Bioprosthetic valve thrombosis (BPVT) is increasingly recognised as a major cause of prosthetic dysfunction in the first years postimplantation. How early abnormal gradients can be detected prior to diagnosis and how fast they normalise with anticoagulant therapy is unknown. We set forth to (1) evaluate patterns of increase in gradients prior to BPVT diagnosis and (2) characterise time-course of response to anticoagulation. METHODS: Patients treated with warfarin for BPVT (1999-2019) with clinically significant reduction of mean gradients (≥25%) were identified retrospectively. Recovery was defined as gradient decrease ≥50%, to postimplantation or to normal-range gradients per position, model and size. Time-to-BPVT (implantation-BPVT diagnosis), potential diagnostic delay (first abnormal gradient by position, model and size-BPVT diagnosis) and time-to-recovery (BPVT diagnosis-complete resolution) were recorded. RESULTS: 77 patients were identified; 32 (42%) aortic (23 surgical-12 porcine, 11 pericardial; 9 transcatheter); 24 (31%) mitral; 21 (27%) tricuspid. Median time-to-BPVT was 24, 21 and 10 months, respectively. Potential diagnostic delay was median 21 months for aortic, 4 months for mitral, but 0 for tricuspid. Recovery was significantly faster in mitral than aortic (median 2.5 vs 4.8 months, p=0.038) and tricuspid (median 5.9 months, p=0.025) positions. Porcine aortic valves responded faster than pericardial aortic valves (median 2.9 vs 20.3 months, p=0.004). CONCLUSION: Gradients start to increase months before the clinical BPVT diagnosis. Recovery is faster in mitral and surgical aortic porcine valves; a longer warfarin trial seems indicated in tricuspid and surgical aortic pericardial valves.
No takes yet. Share an insight, caveat, or question.
Naser et al. (2021) conducted a cohort in Bioprosthetic valve thrombosis (n=77). Mitral valve position vs. Aortic valve position was evaluated on Time-to-recovery (BPVT diagnosis to complete resolution) (p=0.038). In patients treated with warfarin for bioprosthetic valve thrombosis, recovery was faster in mitral than aortic and tricuspid positions.
Synapse has enriched 10 related papers. Consider them for comparative context: