Key result
Oscillometric ankle BP correlates with Doppler but overestimates pressure in ~44% with crural artery occlusion.
Why the study?
Does oscillometric ankle blood pressure measurement correlate with Doppler measurement in patients with peripheral vascular disease?
Observational (n=168)
Non-blinded
Does oscillometric ankle blood pressure measurement correlate with Doppler measurement in patients with peripheral vascular disease?
While oscillometric ankle blood pressure measurement correlates highly with Doppler measurement in peripheral vascular disease, it overestimates pressure in a significant portion of patients with crural artery occlusion and cannot completely replace Doppler.
Caution against replacing Doppler with oscillometry in crural occlusion; leaves open need for validation in peripheral vascular disease.
To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.
No takes yet. Share an insight, caveat, or question.
Nukumizu et al. (2007) conducted an observational in Peripheral vascular disease (n=168). Oscillometric ankle blood pressure measurement vs. Doppler ankle blood pressure measurement was evaluated on Correlation between Doppler and oscillometric ankle pressure measurements (Correlation coefficient 0.928 in AAA and 0.922 in PAOD). Oscillometric ankle blood pressure measurement highly correlated with Doppler measurement (r=0.928 in AAA, r=0.922 in PAOD), but overestimated pressure in 44% of patients with crural artery occlusion.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: