Key result
99mTc-sulfur colloid scintigraphy demonstrates ~84% accuracy for detecting DVT compared to contrast venography.
Why the study?
Does 99mTc-sulfur colloid scintigraphy accurately detect deep venous thrombosis compared to contrast venography in patients with suspected DVT?
Observational (n=25)
Does 99mTc-sulfur colloid scintigraphy accurately detect deep venous thrombosis compared to contrast venography in patients with suspected DVT?
99mTc-sulfur colloid scintigraphy is a relatively noninvasive and accurate method (84% accuracy) for identifying deep venous thrombosis.
Answers are grounded in this paper and cite their sources.
Supports noninvasive DVT detection in select settings; leaves open validation against modern standards in larger cohorts.
Scintigrams of the leg were obtained following antecubital venous injection of 99mTc-sulfur colloid (SC) in 25 patients with suspected deep venous thrombosis. Contrast venograms were taken following the scan in all cases. Of 14 patients with confirmed deep venous thrombosis, 11 had positive scans. Of 11 patients with normal venograms, 10 had negative scintigrams. The simplicity of 99mTc-SC venography and its high rate of accuracy (84% in this series) suggest that it may be useful as a relatively noninvasive means of identifying deep venous thrombosis of the leg.
No takes yet. Share an insight, caveat, or question.
Bardfeld et al. (1983) conducted an observational in suspected deep venous thrombosis (n=25). 99mTc-sulfur colloid scintigraphy vs. contrast venography was evaluated on detection of deep venous thrombosis (84% accuracy). 99mTc-sulfur colloid scintigraphy demonstrated an 84% accuracy rate for detecting deep venous thrombosis compared to contrast venography.
Synapse has enriched 10 related papers. Consider them for comparative context: