Answers are grounded in this paper and cite their sources.
The trend in the dairy and food industry is toward continuous operation with higher temperatures and shorter exposures for processing food products, the objectives being to secure greater destruction of microorganisms and enzymes, to improve keeping quality, to maintain and preserve nutritional properties and palatability and to save time and labor.A small-tube heat exchanger, known as the Mallorizer, was made available to the Illinois Agricultural Experiment Station.Mallory (3), in 1942, obtained a patent for this heat exchanger in which liquid dairy products are forced through small tubes at a high velocity, resulting in turbulent flow and rapid heat transfer.Reynolds (5), in 1883, showed that the thickness of the laminar film was a function of velocity of the liquid across heated surfaces and as the velocity increased turbulent replaced laminar flow.This was confirmed by Prandtl (4) in 1904.This paper deals with the effect of heating cream at different temperatures in the small-tube heat exchanger.Data also are presented to show some of the operating characteristics of this unit.:EXPERIMENTAL PROCEDURE Before conducting experimental work with milk products, it was thought necessary to study some of the operating aspects of the small-tube heat exchanger.This unit consists of three independent heating sections and three cooling sections.Each section has eight lengths of stainless steel tubing, each length being 70.25 in.long and 0.25 in. in internal diameter.The entire length of the tubing in the three heating sections, including the header joints, was calculated to be 142.7 ft.The entire heating section is enclosed in an insulated jacket and is designed for use with high pressure steam.The cooling section is of similar construction and water is used as the coolant.In this study, however, one heating section was disconnected and an additional tube 1.0 in. in internal diameter was attached outside the heating jacket to serve as a holding tube.This reduced the length of the heating section to 95.1 ft.Temperature was regulated with a compressed air-actuated regulator, known commercially as a "Fulscope", which controls the steam pressure.A Manton-Gaulin homogenizer was used as a positive pump to force the product through the exchanger and it operated at about 2,000 p.si.After the product was heated to the desired temperature, it flowed through an insulated holding tube of 1 in.internal diameter and which had a built-in thermocouple.The temperature was determined on a recording potentiometer.
No takes yet. Share an insight, caveat, or question.
Herreid et al. (1952) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: