Key result
Prophylactic ICDs appropriately treat ventricular tachyarrhythmias in ~44% of high-risk coronary patients over 30 months.
Why the study?
What is the incidence and characteristics of spontaneous ventricular tachyarrhythmias in high-risk coronary patients receiving a prophylactic ICD?
Observational (n=41)
What is the incidence and characteristics of spontaneous ventricular tachyarrhythmias in high-risk coronary patients receiving a prophylactic ICD?
High-risk coronary patients with LVEF <35% and inducible VT/VF have a high incidence of appropriate ICD therapies early after implantation, supporting the use of tiered-therapy defibrillators.
Answers are grounded in this paper and cite their sources.
High incidence of appropriate therapies in this observational cohort; hypothesis-generating for prophylactic ICD benefit, pending randomized data.
OBJECTIVES: To assess the incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias after implantable cardioverter-defibrillator (ICD) implantation for primary prevention. DESIGN: Prospective observational study. PATIENTS: 41 consecutive patients, who fulfilled MADIT (multicenter automatic defibrillator implantation trial) I criteria, except for suppressibility by procainamide, and who received a prophylactic ICD. INTERVENTIONS: Subpectoral implantation of an ICD. MAIN OUTCOME MEASURES: Incidence of ventricular tachyarrhythmias and their electrophysiological characteristics with respect to timing of the arrhythmia, tachyarrhythmia cycle length, mode of termination, and clinical relevance. RESULTS: During a mean (SD) follow up of 30 (21) months 18 of 41 (43.9%) patients experienced 142 appropriate ICD treatments. The mean (SD) time to first event was 9.6 (15.1) months. One patient had ventricular fibrillation (VF), 12 patients ventricular tachycardia (VT), and five both VT and VF. The mean (SD) cycle length of monomorphic VT was 306 (42) ms. Of 142 episodes, 117 (82.3%) were terminated by antitachycardia pacing and another 25 (17.6%) by ICD discharges. Cumulative survival of hypothetical death, defined as treated VT with a cycle length < 260 ms or VF, was 83.2% after one year and 78.4% after two years. CONCLUSIONS: Patients with a left ventricular ejection fraction < 35%, a history of myocardial infarction, non-sustained VT, and inducible VT/VF are at high risk of VT/VF early after implantation. Therefore, implantation of a tiered treatment defibrillator seems to be justified.
No takes yet. Share an insight, caveat, or question.
Christian Wolpert (2004) conducted an observational in High risk coronary patients (n=41). Prophylactic implantation of an ICD was evaluated on Incidence of ventricular tachyarrhythmias and their electrophysiological characteristics. During a mean follow-up of 30 months, 43.9% of high-risk coronary patients with a prophylactic ICD experienced appropriate ICD treatments for ventricular tachyarrhythmias.
Synapse has enriched 10 related papers. Consider them for comparative context: