Key result
New hemielliptical model for RV volume from biplane radiographs closely matches directly measured cast volumes.
Why the study?
Does a hemielliptical model accurately calculate right ventricular volume compared to direct measurement in human right ventricle casts?
Population
Silicone rubber casts from 7 adult human right ventricles at autopsy
Comparison
Calculation of right ventricular volume using a… vs Directly measured volume by water displacement
Design
Preclinical
Authors
Loading...
May support RV volumetry from biplane radiographs; leaves open in vivo validation before clinical use.
Does a hemielliptical model accurately calculate right ventricular volume compared to direct measurement in human right ventricle casts?
Effect estimate: r = 0.99
A new hemielliptical model allows for accurate calculation of right ventricular volume from biplane radiographs, closely matching direct measurements.
Boak et al. (1977) studied Right ventricular volume measurement (n=7). Hemielliptical model for calculating right ventricular volume vs. Directly measured volume by water displacement was evaluated on Agreement between calculated volume and displacement volume (r = 0.99). A new hemielliptical model for calculating right ventricular volume from biplane radiographs showed close agreement with directly measured cast volumes (r = 0.99).